High Purity Solvents (n-Butyl Acetate)
Electronic Premium
Electronic Grade Chemical

High Purity Solvents (n-Butyl Acetate)

Ultra-pure electronic grade High Purity Solvents manufactured to meet stringent semiconductor industry specifications. Our electronic grade solvents including n-Butyl Acetate provide exceptional purity with ultra-low contamination for critical semiconductor processing and advanced electronics manufacturing.

  • Electronic Grade Purity
  • Ultra-Low Contamination
  • Superior Solvent Performance
  • Semiconductor Compatible
  • Precise Purity Control
  • Consistent Quality

Electronics Excellence Demands Ultra-Pure Chemicals

Get electronic grade High Purity Solvents for semiconductor manufacturing, explore custom specifications, or discuss process optimization with our electronics specialists.

Get Electronic Grade Quote

Technical Specifications

Purity Range: 99.5% - 99.9%
Grade: Electronic Grade
Water Content: ≤ 10 ppm
Metal Impurities: ≤ 1 ppm total
Particle Count: ≤ 100 per mL
Organic Impurities: ≤ 10 ppm
UV Transmittance: >95% at 280nm
Conductivity: ≤ 1 μS/cm
Residue on Evaporation: ≤ 0.001%
Packaging: 1L, 4L, 20L containers

Applications

Semiconductor Cleaning
Photoresist Processing
Optical Component Cleaning
MEMS Fabrication
Chemical Synthesis
PCB Manufacturing
Precision Cleaning
Advanced Materials
Surface Preparation
Electronic Assembly
Analytical Applications
Quality Control

Industry-Specific Grades

DRAVYOM offers specialized high-purity solvents tailored for specific electronic applications, ensuring optimal performance and regulatory compliance across diverse manufacturing requirements.

Semiconductor Grade
Purity: ≥99.9% Water Content: ≤ 5 ppm Metal Impurities: ≤ 0.1 ppm Application: Wafer cleaning
Optical Grade
Purity: ≥99.8% UV Transmittance: >98% Particle Count: ≤ 50 per mL Application: Optical cleaning
MEMS Grade
Purity: ≥99.7% Organic Impurities: ≤ 5 ppm Residue: ≤ 0.0005% Application: MEMS processing
PCB Grade
Purity: ≥99.5% Conductivity: ≤ 2 μS/cm pH: 6.5-7.5 Application: PCB cleaning

Quality Standards

DRAVYOM's High-Purity Solvents are manufactured under stringent quality control protocols, meeting international electronics standards including SEMI, ASTM, and ISO specifications. Our electronic-grade production ensures consistent performance and regulatory compliance.

ISO 9001:2015 Certified Manufacturing
SEMI Standards Compliance
≥99.5% Purity Guarantee
Advanced Quality Testing
Ultra-Low Impurity Levels
Batch-to-Batch Consistency
Traceable Certificate of Analysis
Controlled Environment Storage

Advanced Chemical Properties & Performance

Electronic Grade High-Purity Solvents exhibit exceptional chemical properties essential for precision semiconductor and electronics manufacturing applications. The ultra-pure composition and controlled specifications ensure reliable performance in demanding electronic cleaning and processing operations.

Solvent Properties
Evaporation Rate: Fast & complete
Residue Level: ≤ 1 ppm
Surface Tension: Low wetting
Dielectric Strength: High breakdown
Physical Properties
Boiling Point Range: Varies by solvent
Density: Specific to type
Vapor Pressure: Controlled range
Flash Point: Safety classified
Chemical Properties
Chemical Compatibility: Electronics materials
Reactivity: Inert to substrates
Stability: Long-term stable
pH (aqueous): 6.5-7.5 neutral
Purity Specifications
Minimum Purity: ≥ 99.5%
Water Content: ≤ 50 ppm
Metal Impurities: ≤ 1 ppm total
Particle Count: ≤ 100 (>0.5µm)/mL
Performance Properties
Cleaning Efficiency: 99.9% removal
Drying Time: Rapid evaporation
Conductivity: ≤ 2 µS/cm
Shelf Life: 2+ years sealed

Performance Characteristics

Detailed performance metrics demonstrate Electronic Grade High-Purity Solvent superiority in electronics applications with exceptional cleaning power, fast evaporation, and contamination-free processing.

Excellent Cleaning

99.9% contaminant removal

Superior cleaning power
Fast Evaporation

Rapid drying

No residue left
Ultra-Pure

≥ 99.5% purity

Minimal contamination
Material Safe

Compatible with electronics

No substrate damage
Low Residue

≤ 1 ppm after evaporation

Clean finish
Long Shelf Life

2+ years stability

Reliable storage

Safety Information

Most electronic-grade solvents are flammable liquids that may cause skin and eye irritation. Vapors may be harmful if inhaled. Handle with appropriate protective equipment including chemical-resistant gloves, safety goggles, and ensure adequate ventilation. Keep away from ignition sources.

Flammable
Irritant
Vapor Hazard

Storage & Handling

Store in original containers in a cool, dry place away from heat and ignition sources. Use in well-ventilated areas with appropriate solvent handling equipment. Maintain temperature control and ensure proper waste disposal according to local regulations.

Cool storage (< 25°C)
Away from ignition sources
Excellent ventilation
Proper waste disposal

Chemical Mechanisms & Reaction Pathways

High purity solvents exhibit controlled dissolution and evaporation chemistry to provide exceptional cleaning and processing performance in semiconductor manufacturing with predictable solvent properties and residue-free processing.

Dissolution Mechanisms

Selective solvent action for diverse contaminant removal

Effective cleaning across material types
Evaporation Kinetics

Controlled vapor pressure for residue-free drying

Clean evaporation without contamination
Surface Interactions

Optimized wetting and penetration properties

Complete cleaning of complex geometries
Azeotropic Behavior

Controlled vapor composition for process optimization

Predictable distillation and recovery

Regulatory Compliance & Documentation

Comprehensive regulatory compliance ensures global semiconductor facility access with complete documentation packages supporting international electronics manufacturing standards and solvent processing qualifications.

SEMI Standards

Semiconductor Equipment and Materials International compliance

Solvent Specifications

Electronic grade solvent purity and performance standards

Chemical Purity Standards

Ultra-high purity solvent specifications and contamination limits

Transport Regulations

Hazardous material transport and shipping compliance

Process Validation

Supported cleaning process qualification documentation

SDS Documentation

Multi-language Safety Data Sheets (16 sections, GHS compliant)

Technical Support & Value-Added Services

DRAVYOM's semiconductor process team provides comprehensive solvent support, process optimization assistance, and analytical services to maximize solvent performance in your specific manufacturing applications.

Process Development
  • Cleaning process optimization support
  • Solvent selection and compatibility guidance
  • Distillation and recovery optimization
  • Custom solvent blend development
Analytical Services
  • Purity analysis and contamination monitoring
  • Residue testing and validation
  • Solvent recovery analysis
  • Cleaning process qualification support
Technical Support
  • Solvent handling troubleshooting consultation
  • Equipment compatibility guidance
  • Safety training and protocols
  • Semiconductor cleaning best practices
Supply Solutions
  • Bulk solvent delivery systems
  • Emergency solvent supply arrangements
  • Custom packaging and dispensing
  • Global specialty solvent network

Environmental Impact & Sustainability

Our high purity solvent production emphasizes environmental responsibility through sustainable manufacturing practices, solvent recovery, and comprehensive environmental impact management for semiconductor operations.

Solvent Recovery

Advanced distillation and recycling systems

VOC Control

Volatile organic compound capture and treatment systems

Clean Production

Energy-efficient manufacturing with emission controls

Safe Disposal

Comprehensive guidance for solvent waste management

ISO 14001

Environmental management system certified production

Container Recycling

Solvent container return and recycling programs

Manufacturing Excellence & Quality Control

DRAVYOM's state-of-the-art solvent manufacturing facility employs advanced purification technology and continuous monitoring systems to ensure consistent high purity solvent quality and performance across all production batches.

Production Process

Advanced multi-column distillation and purification systems

Multi-stage processing for ultra-high purity
Quality Testing

30-point analytical testing protocol including trace impurities and moisture

GC-MS analysis and performance validation
Quality Systems

ISO 9001:2015 quality management with electronics solvent accreditation

Continuous improvement and process validation
Packaging Control

Ultra-clean containers with contamination prevention systems

Purity preservation and stability assurance

Market Applications & Performance Data

Comprehensive semiconductor manufacturing data demonstrating high purity solvent effectiveness across diverse processing applications with quantified performance metrics and process validations.

Semiconductor Cleaning
Purity: >99.9% analytical grade Water Content: <10 ppm moisture Residue: <0.1 ppm non-volatile
Process Applications
Surface Quality: <0.1 nm roughness Evaporation Rate: Controlled kinetics Contamination: Zero metallic impurities
Manufacturing Efficiency
Recovery Rate: >95% solvent recovery Throughput: 40% faster processing Yield: 99.9%+ process success

DRAVYOM Competitive Advantages

Superior Purity

Consistently exceeds semiconductor specifications with ultra-pure solvent formulations and exceptional cleaning performance

Reliable Supply

Guaranteed availability with specialized logistics and high purity solvent production scheduling

Solvent Expertise

Dedicated solvent chemistry team provides formulation development and troubleshooting support

Quality Assurance

Traceable certificates with comprehensive analytical data and solvent validation support

Global Standards

International compliance with SEMI and electronics specifications for worldwide acceptance

Partnership Approach

Collaborative relationships with semiconductor manufacturers and custom solvent development services