Ethanol (Electronic Grade)
Electronic Premium
Electronic Grade Chemical

Ethanol (Electronic Grade)

Ultra-pure electronic grade Ethanol manufactured to meet stringent semiconductor industry specifications. Our electronic grade C₂H₅OH provides exceptional purity with ultra-low contamination for critical semiconductor processing and advanced electronics manufacturing.

  • Electronic Grade Purity
  • Ultra-Low Contamination
  • Superior Solvent Performance
  • Semiconductor Compatible
  • Precise Purity Control
  • Consistent Quality

Technical Specifications

Chemical Name: Ethanol (Electronic Grade)
Chemical Formula: C₂H₅OH
CAS Number: 64-17-5
Purity: ≥ 99.9%
Water Content: ≤ 0.05%
Physical State: Clear colorless liquid
Density (20°C): 0.789-0.792 g/cm³
Boiling Point: 78.3°C
Flash Point: 13°C
Viscosity (20°C): 1.2 cP
Metal Impurities (Na): ≤ 0.1 ppm
Metal Impurities (K): ≤ 0.1 ppm
Metal Impurities (Total): ≤ 1 ppm
Chloride (Cl⁻): ≤ 1 ppm
Sulfate (SO₄²⁻): ≤ 1 ppm
Particle Count: ≤ 50 per mL (≥0.3μm)
Residue on Evaporation: ≤ 1 ppm
Packaging Options: 1L, 4L, 20L containers

Applications

Semiconductor Cleaning
Semiconductor Processing
Photoresist Processing
Wafer Cleaning
Surface Preparation
Solvent Applications
Quality Control
Research Applications
Chemical Synthesis
Academic Research
Process Development
Extraction Processes

Industry-Specific Grades

DRAVYOM offers specialized electronic grade ethanol formulations tailored for specific semiconductor processing requirements, ensuring optimal purity levels, low water content, and minimal metal contamination for diverse cleaning and processing applications.

Ultra-Pure Grade
Purity: ≥99.95% Water: ≤0.02% Sub-ppm Metals Application: Critical cleaning
Standard Electronic
Purity: ≥99.9% Water: ≤0.05% Low Metal Content Application: General processing
Research Grade
Custom Specifications Small Volumes: Available Isotopic Purity Application: R&D applications
Analytical Grade
Purity: ≥99.8% Trace Analysis Certified COA Application: Analysis

Quality Standards

DRAVYOM's Electronic Grade Ethanol is manufactured under stringent quality control protocols, meeting international semiconductor industry standards including SEMI, JEIDA, and ISO specifications. Our formulations ensure consistent purity and regulatory compliance.

ISO 9001:2015 Certified Manufacturing
SEMI Standards Compliance
Electronic Grade Purity
Advanced Chemical Analysis
Ultra-Low Metal Contamination
Batch-to-Batch Consistency
Complete Certificate of Analysis
Safe Handling & Delivery

Advanced Chemical Properties & Performance

Electronic Grade Ethanol exhibits exceptional chemical properties essential for precision semiconductor cleaning and processing applications. The ultra-pure composition and water-free formulation ensure reliable performance in demanding electronic manufacturing processes.

Cleaning Properties
Solvent Power: Excellent for organics
Drying Rate: Fast evaporation
Residue Level: < 1 ppm non-volatile
Surface Compatibility: Si, metals, polymers
Physical Properties
Boiling Point: 78.3°C
Density (20°C): 0.789 g/cm³
Vapor Pressure: 59 mmHg @20°C
Surface Tension: 22.3 mN/m
Chemical Properties
Molecular Formula: C₂H₅OH
Molecular Weight: 46.07 g/mol
Flash Point: 13°C (closed cup)
Autoignition: 363°C
Purity Specifications
Minimum Purity: ≥ 99.999% (5N)
Water Content: ≤ 10 ppm
Metal Impurities: ≤ 1 ppb each
Particle Count: ≤ 10 (>0.5µm)/mL
Stability Properties
Shelf Life: 2 years (sealed)
Storage Temperature: 15-25°C
UV Sensitivity: Store in dark
Oxidation Stability: Inert atmosphere preferred

Performance Characteristics

Detailed performance metrics demonstrate Electronic Grade Ethanol superiority in semiconductor applications with exceptional cleaning power, fast drying, and ultra-low contamination levels.

Cleaning Efficiency

Excellent organic removal

Superior degreasing
Fast Drying

Rapid evaporation rate

No drying spots
Ultra-Pure

≥ 99.999% purity

Minimal contamination
Water-Free

≤ 10 ppm water content

Anhydrous grade
Low Residue

< 1 ppm non-volatile

Clean evaporation
Material Safe

Compatible with electronics

No damage to substrates

Safety Information

Highly flammable liquid and vapor that can cause eye irritation and drowsiness if inhaled. May cause skin dryness. Handle with appropriate protective equipment including chemical-resistant gloves, safety goggles, and ensure adequate ventilation. Keep away from heat sources and open flames.

Flammable
Irritant
Vapor Hazard

Storage & Handling

Store in original containers in a cool, dry, well-ventilated area away from heat sources, sparks, and open flames. Keep containers tightly sealed when not in use. Use explosion-proof electrical equipment and grounding procedures to prevent static buildup.

Cool storage (15-25°C)
Away from ignition sources
Well ventilated area
Grounding required

Chemical Mechanisms & Reaction Pathways

Electronic grade ethanol exhibits controlled solvent chemistry and purification mechanisms to provide exceptional cleaning and rinsing performance in semiconductor manufacturing with predictable evaporation rates and residue-free processing.

Dissolution Mechanism

Polar solvent action for organic contaminant removal

Effective cleaning of diverse residues
Evaporation Kinetics

Controlled vapor pressure for residue-free drying

Clean evaporation without contamination
Surface Interactions

Low surface tension for complete wetting and cleaning

Optimized for semiconductor surfaces
Azeotropic Behavior

Water miscibility for controlled drying processes

Predictable vapor composition control

Regulatory Compliance & Documentation

Comprehensive regulatory compliance ensures global semiconductor facility access with complete documentation packages supporting international electronics manufacturing standards and cleaning process qualifications.

SEMI Standards

Semiconductor Equipment and Materials International compliance

Cleaning Specifications

Semiconductor cleaning process and equipment standards

Solvent Purity Standards

Electronic grade solvent purity and contamination specifications

Transport Regulations

Flammable liquid transport and handling compliance

Process Validation

Supported cleaning process qualification documentation

SDS Documentation

Multi-language Safety Data Sheets (16 sections, GHS compliant)

Technical Support & Value-Added Services

DRAVYOM's semiconductor process team provides comprehensive cleaning support, process optimization assistance, and analytical services to maximize ethanol performance in your specific semiconductor manufacturing applications.

Process Development
  • Cleaning process optimization support
  • Solvent compatibility guidance
  • Drying rate optimization and validation
  • Custom concentration development
Analytical Services
  • Purity analysis and monitoring
  • Residue testing and validation
  • Contamination analysis and testing
  • Cleaning process qualification support
Technical Support
  • Cleaning troubleshooting consultation
  • Equipment compatibility guidance
  • Safety training and protocols
  • Semiconductor cleaning best practices
Supply Solutions
  • Bulk solvent delivery systems
  • Emergency ethanol supply arrangements
  • Custom packaging and dispensing
  • Global electronic chemical network

Environmental Impact & Sustainability

Our electronic grade ethanol production emphasizes environmental responsibility through sustainable manufacturing practices, solvent recovery, and comprehensive environmental impact management for semiconductor cleaning operations.

Solvent Recovery

Advanced distillation and recycling systems

VOC Control

Volatile organic compound capture and treatment systems

Clean Production

Energy-efficient manufacturing with emission controls

Safe Disposal

Comprehensive guidance for ethanol waste management

ISO 14001

Environmental management system certified production

Container Recycling

Solvent container return and recycling programs

Manufacturing Excellence & Quality Control

DRAVYOM's state-of-the-art ethanol manufacturing facility employs advanced distillation technology and continuous monitoring systems to ensure consistent electronic grade ethanol quality and performance across all production batches.

Production Process

Advanced multi-column distillation in controlled clean environment

Multi-stage purification for electronic grade quality
Quality Testing

25-point analytical testing protocol including trace impurities and moisture

GC-MS verification and purity validation
Quality Systems

ISO 9001:2015 quality management with electronics solvent accreditation

Continuous improvement and process validation
Packaging Control

Moisture-barrier containers with contamination prevention

Purity preservation and stability assurance

Market Applications & Performance Data

Comprehensive semiconductor manufacturing data demonstrating ethanol effectiveness across diverse cleaning applications with quantified performance metrics and process validations.

Semiconductor Cleaning
Purity: >99.9% analytical grade Water Content: <50 ppm moisture Residue: <1 ppm non-volatile
Wafer Processing
Surface Quality: <0.1 nm roughness Drying Rate: 15 seconds at 25°C Contamination: Zero metallic impurities
Electronics Assembly
Cleaning Efficiency: >99% flux removal Throughput: 50% faster processing Yield: 99.9%+ cleaning success

DRAVYOM Competitive Advantages

Superior Purity

Consistently exceeds semiconductor specifications with ultra-pure ethanol formulations and exceptional cleaning performance

Reliable Supply

Guaranteed availability with specialized logistics and electronic-grade solvent production scheduling

Cleaning Expertise

Dedicated cleaning process team provides optimization guidance and troubleshooting support

Quality Assurance

Traceable certificates with comprehensive analytical data and cleaning validation support

Global Standards

International compliance with SEMI and electronics specifications for worldwide acceptance

Partnership Approach

Collaborative relationships with semiconductor manufacturers and custom solvent development services

Electronics Excellence Demands Ultra-Pure Chemicals

Get electronic grade Ethanol for semiconductor manufacturing, explore custom specifications, or discuss process optimization with our electronics specialists.

Get Electronic Grade Quote