Ethanol (Electronic Grade)
Ultra-pure electronic grade Ethanol manufactured to meet stringent semiconductor industry specifications. Our electronic grade C₂H₅OH provides exceptional purity with ultra-low contamination for critical semiconductor processing and advanced electronics manufacturing.
- Electronic Grade Purity
- Ultra-Low Contamination
- Superior Solvent Performance
- Semiconductor Compatible
- Precise Purity Control
- Consistent Quality
Technical Specifications
Applications
Industry-Specific Grades
DRAVYOM offers specialized electronic grade ethanol formulations tailored for specific semiconductor processing requirements, ensuring optimal purity levels, low water content, and minimal metal contamination for diverse cleaning and processing applications.
Ultra-Pure Grade
Standard Electronic
Research Grade
Analytical Grade
Quality Standards
DRAVYOM's Electronic Grade Ethanol is manufactured under stringent quality control protocols, meeting international semiconductor industry standards including SEMI, JEIDA, and ISO specifications. Our formulations ensure consistent purity and regulatory compliance.
Advanced Chemical Properties & Performance
Electronic Grade Ethanol exhibits exceptional chemical properties essential for precision semiconductor cleaning and processing applications. The ultra-pure composition and water-free formulation ensure reliable performance in demanding electronic manufacturing processes.
Cleaning Properties
Physical Properties
Chemical Properties
Purity Specifications
Stability Properties
Performance Characteristics
Detailed performance metrics demonstrate Electronic Grade Ethanol superiority in semiconductor applications with exceptional cleaning power, fast drying, and ultra-low contamination levels.
Cleaning Efficiency
Excellent organic removal
Superior degreasingFast Drying
Rapid evaporation rate
No drying spotsUltra-Pure
≥ 99.999% purity
Minimal contaminationWater-Free
≤ 10 ppm water content
Anhydrous gradeLow Residue
< 1 ppm non-volatile
Clean evaporationMaterial Safe
Compatible with electronics
No damage to substratesSafety Information
Highly flammable liquid and vapor that can cause eye irritation and drowsiness if inhaled. May cause skin dryness. Handle with appropriate protective equipment including chemical-resistant gloves, safety goggles, and ensure adequate ventilation. Keep away from heat sources and open flames.
Storage & Handling
Store in original containers in a cool, dry, well-ventilated area away from heat sources, sparks, and open flames. Keep containers tightly sealed when not in use. Use explosion-proof electrical equipment and grounding procedures to prevent static buildup.
Chemical Mechanisms & Reaction Pathways
Electronic grade ethanol exhibits controlled solvent chemistry and purification mechanisms to provide exceptional cleaning and rinsing performance in semiconductor manufacturing with predictable evaporation rates and residue-free processing.
Dissolution Mechanism
Polar solvent action for organic contaminant removal
Effective cleaning of diverse residuesEvaporation Kinetics
Controlled vapor pressure for residue-free drying
Clean evaporation without contaminationSurface Interactions
Low surface tension for complete wetting and cleaning
Optimized for semiconductor surfacesAzeotropic Behavior
Water miscibility for controlled drying processes
Predictable vapor composition controlRegulatory Compliance & Documentation
Comprehensive regulatory compliance ensures global semiconductor facility access with complete documentation packages supporting international electronics manufacturing standards and cleaning process qualifications.
SEMI Standards
Semiconductor Equipment and Materials International compliance
Cleaning Specifications
Semiconductor cleaning process and equipment standards
Solvent Purity Standards
Electronic grade solvent purity and contamination specifications
Transport Regulations
Flammable liquid transport and handling compliance
Process Validation
Supported cleaning process qualification documentation
SDS Documentation
Multi-language Safety Data Sheets (16 sections, GHS compliant)
Technical Support & Value-Added Services
DRAVYOM's semiconductor process team provides comprehensive cleaning support, process optimization assistance, and analytical services to maximize ethanol performance in your specific semiconductor manufacturing applications.
Process Development
- Cleaning process optimization support
- Solvent compatibility guidance
- Drying rate optimization and validation
- Custom concentration development
Analytical Services
- Purity analysis and monitoring
- Residue testing and validation
- Contamination analysis and testing
- Cleaning process qualification support
Technical Support
- Cleaning troubleshooting consultation
- Equipment compatibility guidance
- Safety training and protocols
- Semiconductor cleaning best practices
Supply Solutions
- Bulk solvent delivery systems
- Emergency ethanol supply arrangements
- Custom packaging and dispensing
- Global electronic chemical network
Environmental Impact & Sustainability
Our electronic grade ethanol production emphasizes environmental responsibility through sustainable manufacturing practices, solvent recovery, and comprehensive environmental impact management for semiconductor cleaning operations.
Solvent Recovery
Advanced distillation and recycling systems
VOC Control
Volatile organic compound capture and treatment systems
Clean Production
Energy-efficient manufacturing with emission controls
Safe Disposal
Comprehensive guidance for ethanol waste management
ISO 14001
Environmental management system certified production
Container Recycling
Solvent container return and recycling programs
Manufacturing Excellence & Quality Control
DRAVYOM's state-of-the-art ethanol manufacturing facility employs advanced distillation technology and continuous monitoring systems to ensure consistent electronic grade ethanol quality and performance across all production batches.
Production Process
Advanced multi-column distillation in controlled clean environment
Multi-stage purification for electronic grade qualityQuality Testing
25-point analytical testing protocol including trace impurities and moisture
GC-MS verification and purity validationQuality Systems
ISO 9001:2015 quality management with electronics solvent accreditation
Continuous improvement and process validationPackaging Control
Moisture-barrier containers with contamination prevention
Purity preservation and stability assuranceMarket Applications & Performance Data
Comprehensive semiconductor manufacturing data demonstrating ethanol effectiveness across diverse cleaning applications with quantified performance metrics and process validations.
Semiconductor Cleaning
Wafer Processing
Electronics Assembly
DRAVYOM Competitive Advantages
Superior Purity
Consistently exceeds semiconductor specifications with ultra-pure ethanol formulations and exceptional cleaning performance
Reliable Supply
Guaranteed availability with specialized logistics and electronic-grade solvent production scheduling
Cleaning Expertise
Dedicated cleaning process team provides optimization guidance and troubleshooting support
Quality Assurance
Traceable certificates with comprehensive analytical data and cleaning validation support
Global Standards
International compliance with SEMI and electronics specifications for worldwide acceptance
Partnership Approach
Collaborative relationships with semiconductor manufacturers and custom solvent development services
Electronics Excellence Demands Ultra-Pure Chemicals
Get electronic grade Ethanol for semiconductor manufacturing, explore custom specifications, or discuss process optimization with our electronics specialists.
Get Electronic Grade Quote