Laboratory Oxidizer
Laboratory Reagent

LR Grade Chromic Acid Solution (H₂CrO₄)

Laboratory Reagent grade Chromic Acid Solution manufactured for oxidation reactions, cleaning applications, and educational experiments. Our LR grade H₂CrO₄ provides reliable oxidizing agent for standard laboratory work, teaching applications, and analytical procedures.

  • Laboratory Grade Purity
  • Strong Oxidizing Properties
  • Cleaning Applications
  • Educational & Training Use
  • Cost-Effective Laboratory Solution
  • Consistent Quality & Performance

Technical Specifications

Chemical Formula: H₂CrO₄ (in aqueous solution)
CAS Number: 7738-94-5
EINECS Number: 231-801-5
Concentration: 10% w/v (LR Grade)
Physical State: Orange-red liquid solution
Density (20°C): 1.05 g/cm³
Molecular Weight: 118.01 g/mol
pH: < 1.0 (strongly acidic)
Boiling Point: 100°C (decomposes)
Oxidizing Power: Very strong oxidizing agent
Chloride (Cl): ≤ 0.001%
Sulfate (SO₄): ≤ 0.005%
Iron (Fe): ≤ 0.001%
Heavy Metals (as Pb): ≤ 0.002%
Storage Conditions: Cool, dry place, away from organics
Packaging Options: 500ml, 1L bottles

Applications

Educational Laboratories
Oxidation Reactions
Cleaning Agent
Analytical Chemistry
Etching Solutions
Organic Oxidation
Surface Treatment
Metal Analysis
Dichromate Testing
Quality Control Testing

Industry-Specific Grades

DRAVYOM offers specialized chromic acid solution grades tailored for different laboratory and analytical requirements, ensuring optimal performance and safety across diverse oxidation and surface treatment applications.

LR Grade (Laboratory Reagent)
Concentration: 10% w/v Chloride: ≤ 0.001% Heavy Metals: ≤ 0.002% Application: General laboratory, educational use
Technical Grade
Concentration: 15% w/v Cost-effective Industrial purity Application: Surface treatment
Educational Grade
Concentration: 5% w/v Safety: Diluted concentration Documentation: Complete SDS Application: Teaching institutions
Analytical Grade
Concentration: 20% w/v Ultra-low impurities High oxidizing power Application: Analytical procedures

Quality Standards

DRAVYOM's LR Grade Chromic Acid Solution is manufactured under stringent quality control protocols, meeting international standards for laboratory and educational applications. Our production ensures consistent oxidizing power and concentration stability.

ISO 9001:2015 Certified Manufacturing
Laboratory Reagent Standards
10% Reliable Concentration
Oxidizing Power Verified
Educational Grade Compliance
Consistent Solution Performance
Certificate of Analysis
Hazardous Material Transport

Advanced Chemical Properties & Performance

LR Grade Chromic Acid Solution exhibits excellent oxidizing properties and cleaning characteristics, making it suitable for controlled educational demonstrations and specialized laboratory applications requiring powerful oxidation reactions and glass cleaning procedures.

Oxidizing Properties
Active Species: H₂CrO₄, HCrO₄⁻, Cr₂O₇²⁻
Redox Potential: +1.33 V (Cr₂O₇²⁻/Cr³⁺)
Oxidation: Cr₂O₇²⁻ + 14H⁺ + 6e⁻ → 2Cr³⁺ + 7H₂O
Color Change: Orange (Cr⁶⁺) to green (Cr³⁺)
Cleaning Properties
Glass Cleaning: Removes organic residues completely
Mechanism: Oxidative decomposition of organics
Effectiveness: Superior to other cleaning agents
Concentration: 10% H₂CrO₄ in water
Physical Properties
pH: Strongly acidic (pH < 1)
Density: 1.05 g/cm³ (10% solution)
Solubility: Completely miscible with water
Appearance: Dark orange-red solution

Performance Characteristics

Performance metrics demonstrate LR Grade Chromic Acid Solution reliability in specialized educational and laboratory applications with consistent oxidizing performance and cleaning capabilities for controlled procedures.

Oxidizing Performance

Effectiveness: Excellent oxidation reactions

Consistent chromium redox chemistry
Cleaning Performance

Removal: Superior organic residue cleaning

Complete glassware decontamination
Usage Restriction

Access: Extremely limited educational use

Advanced research facilities only
Safety Priority

Control: Strict carcinogen protocols

Hexavalent chromium hazard

Safety Information

Highly carcinogenic and corrosive chromium compound that poses extreme health risks through all exposure routes. Strong oxidizer that can cause explosions with organic materials. Prohibited in educational settings. Use only in specialized research facilities with expert supervision, fume hoods, and comprehensive carcinogen safety protocols.

Highly Carcinogenic
Highly Corrosive
Educational Prohibition

Storage & Handling

Store in specialized carcinogen storage areas with excellent ventilation, corrosion-resistant containers, and restricted access. Use comprehensive safety protocols with emergency response procedures and detailed regulatory compliance tracking for research applications only.

Room temperature storage
Excellent ventilation required
Maximum security storage
Corrosion-resistant containers

Chemical Mechanisms & Reaction Pathways

Chromic acid solution exhibits strong oxidizing and corrosive properties through chromium(VI) chemistry, making it suitable for specialized research applications requiring controlled oxidation reactions under strict safety protocols.

Strong Oxidation

Cr₂O₇²⁻ + 14H⁺ + 6e⁻ → 2Cr³⁺ + 7H₂O

Powerful oxidizing agent for research
Corrosive Action

Attacks organic materials and metals

Requires specialized handling protocols
Analytical Applications

Used in specialized analytical procedures

Critical for certain research methods
Organic Oxidations

Oxidizes alcohols and other organic substrates

Important for synthetic chemistry research

Regulatory Compliance & Documentation

Comprehensive regulatory compliance ensures safe use of carcinogenic oxidizing materials in specialized research environments with complete documentation supporting institutional safety and regulatory requirements.

Research Standards

Compliance with research institution safety for carcinogenic oxidizers

Carcinogen Classification

Strict hazard classification and handling protocols

Safety Compliance

Occupational safety standards for carcinogenic exposure

Transportation

Hazmat classification for carcinogenic oxidizers

Technical Support & Value-Added Services

DRAVYOM's specialized research support team provides comprehensive guidance for safe handling of carcinogenic oxidizing materials and technical assistance for LR Grade Chromic Acid Solution applications.

Research Support
  • Carcinogen safety training programs
  • Specialized oxidation development
  • Researcher safety protocol guidance
  • Regulatory compliance assistance
Oxidation Services
  • Oxidation procedure guidance
  • Safety optimization consultation
  • Alternative method development
  • Waste disposal assistance

Environmental Impact & Sustainability

Our LR Grade Chromic Acid Solution production emphasizes environmental responsibility with controlled manufacturing and comprehensive environmental impact management for specialized research applications with proper waste treatment.

Controlled Production

Environmentally controlled manufacturing processes

Research Sustainability

Supporting sustainable research practices with proper disposal

Safe Disposal

Specialized disposal guidance for chromium waste

Container Programs

Specialized hazardous container return programs

Manufacturing Excellence & Quality Control

DRAVYOM's specialized manufacturing facility employs controlled production technology for consistent LR Grade Chromic Acid Solution quality and oxidizing performance under strict safety and environmental controls.

Production Process

Controlled synthesis with concentration and safety management

Consistent quality under strict safety protocols
Oxidation Testing

Oxidizing potential verification and contamination testing protocols

Regular oxidation performance monitoring
Safety Systems

Enhanced safety protocols for carcinogenic oxidizer production

Comprehensive safety and environmental management

Market Applications & Performance Data

Comprehensive research data demonstrating LR Grade Chromic Acid Solution effectiveness across specialized research applications with reliable oxidizing performance under strict safety protocols.

Research Institutions
Safety Record: 99.9% incident-free handling Performance: Consistent oxidation efficiency Compliance: Full regulatory documentation
Analytical Laboratories
Oxidizing Power: Superior analytical performance Quality: Meets specialized research standards Customer Satisfaction: 98% approval under safety protocols

DRAVYOM Competitive Advantages

Oxidation Expertise

Specialized knowledge in chromium chemistry and safety protocols for research environments

Research Focus

Dedicated support for research institutions with carcinogen safety training

Safety Leadership

Enhanced safety protocols specifically designed for carcinogenic oxidizers

Reliable Supply

Consistent availability with research institution safety programs

Quality Consistency

Consistent oxidizing performance with full regulatory documentation

Partnership Approach

Long-term relationships with research institutions and specialized safety support