Chromium Trioxide (Chromic Acid)
Electroplating grade Chromium Trioxide manufactured for chrome plating, hard chrome electroplating, and decorative chrome finishing. Our high-purity chromic acid provides exceptional chrome deposition for automotive components, industrial machinery, and decorative applications.
- Electroplating Grade Purity
- Chrome Electroplating
- Hard Chrome Coating
- Decorative Finishing
- Automotive Applications
- Industrial Grade
Technical Specifications
Applications
Industry-Specific Grades
DRAVYOM offers specialized chromium trioxide grades tailored for specific chrome plating requirements, ensuring optimal performance and regulatory compliance across diverse industrial and decorative applications.
Hard Chrome Grade
Decorative Grade
Automotive Grade
Industrial Grade
Quality Standards
DRAVYOM's Chromium Trioxide is manufactured under stringent quality control protocols, meeting international chrome plating standards including ASTM, SAE, and automotive industry specifications. Our electroplating-grade production ensures consistent performance and regulatory compliance.
Advanced Chemical Properties & Performance
Electroplating Grade Chromium Trioxide exhibits exceptional electrochemical properties essential for decorative and hard chromium plating applications. Its ultra-pure composition and controlled crystalline structure ensure reliable performance in demanding electroplating processes and surface hardening operations.
Electrochemical Properties
Physical Properties
Plating Performance
Purity Specifications
Stability Properties
Performance Characteristics
Detailed performance metrics demonstrate Electroplating Grade Chromium Trioxide superiority in hard chrome plating applications with exceptional surface hardness, wear resistance, and decorative finish quality across diverse electroplating processes and industrial applications.
Surface Hardness
Hardness: 800-1000 HV microhardness
Exceptional mechanical propertiesWear Resistance
Abrasion resistance: >10x base metal
Superior durability characteristicsSurface Finish
Surface roughness: Ra ≤ 0.05 μm achievable
Mirror-bright finish qualityOperating Range
Temperature range: 45-65°C optimal
Controlled temperature operationDeposit Adhesion
Bond strength: ≥ 35 N/cm² typical
Excellent substrate bondingBath Stability
Operating life: 6-12 months continuous
Extended process stabilitySafety Information
Chromium Trioxide is a strong oxidizer and carcinogen that causes severe burns and may cause cancer. Handle only with appropriate engineering controls, respiratory protection, and personal protective equipment. Use in well-ventilated areas with proper exhaust systems. Follow all occupational exposure limits and safety protocols.
Storage & Handling
Store in original containers in a cool, dry, well-ventilated area away from combustible materials, reducing agents, and organic substances. Use only with proper engineering controls and containment systems. Ensure emergency procedures and spill response equipment are readily available.
Chemical Mechanisms & Reaction Pathways
Chromium Trioxide exhibits complex chromate chemistry through hexavalent chromium oxidation and electrochemical reduction mechanisms, enabling precise chromium deposition and superior corrosion protection with controlled plating characteristics.
Chromate Formation
CrO₃ + H₂O → H₂CrO₄ ⇌ H⁺ + HCrO₄⁻ (chromic acid equilibrium)
Controlled chromium ion generation for platingElectrochemical Reduction
Cr⁶⁺ + 6e⁻ → Cr⁰ (cathodic chromium deposition)
Multi-electron transfer for metallic chromiumPassivation Mechanism
Surface oxide formation for enhanced corrosion resistance
Self-healing protective layer developmentpH Control
Acid equilibrium management for stable chromium chemistry
Consistent deposition rate controlRegulatory Compliance & Documentation
Comprehensive regulatory compliance ensures controlled chromium compound access with complete documentation packages supporting international standards and hexavalent chromium safety protocols.
Chrome Plating Standards
ASTM B177 and SAE specifications for chromium electroplating
OSHA Compliance
Workplace safety standards for hexavalent chromium exposure
EPA Regulations
Environmental protection standards for chromium discharge
REACH Authorization
European Union restricted substances authorization required
RoHS Restrictions
Electronics industry hexavalent chromium limitations
DOT Hazmat
Dangerous goods transportation and shipping protocols
Technical Support & Value-Added Services
DRAVYOM's chromium plating specialists provide comprehensive chrome process support, safety training, and bath optimization to maximize Chromium Trioxide performance while ensuring regulatory compliance.
Bath Chemistry
- Chromic acid concentration optimization
- Catalyst ratio adjustment protocols
- Temperature and current density optimization
- Bath contamination troubleshooting
Safety & Compliance
- Hexavalent chromium safety training
- Personal protective equipment selection
- Ventilation system design consultation
- Regulatory compliance auditing
Process Optimization
- Chrome deposit thickness control
- Surface finish enhancement techniques
- Corrosion testing and validation
- Quality control implementation
Waste Management
- Chromium waste treatment solutions
- Reduction and precipitation protocols
- Wastewater treatment system design
- Environmental monitoring support
Environmental Impact & Sustainability
Our Chromium Trioxide operations emphasize stringent environmental controls through advanced emission monitoring, chromium waste reduction, and comprehensive environmental impact management for responsible chrome plating.
Emission Control
Advanced scrubbing systems for chromium mist capture
Chromium Recovery
Electrochemical reduction and recovery systems
Wastewater Treatment
Chromium precipitation and water recycling programs
Safe Handling
Comprehensive containment and exposure prevention
ISO 14001
Environmental management system certified operations
Monitoring Systems
Continuous environmental and workplace monitoring
Manufacturing Excellence & Quality Control
DRAVYOM's specialized chromium compound manufacturing facility employs controlled oxidation processes with stringent containment systems to ensure consistent Chromium Trioxide quality while maintaining the highest safety standards.
Production Process
Controlled chromium oxidation with advanced emission control
High-purity chromium trioxide crystallizationQuality Testing
15-point analytical testing including chromium content and trace metals
ICP-MS verification and purity analysisSafety Systems
Comprehensive containment with emergency response protocols
Worker protection and environmental monitoringSecure Packaging
Specialized containers with safety labeling and documentation
DOT compliant hazardous materials packagingMarket Applications & Performance Data
Comprehensive chromium plating data demonstrating Chromium Trioxide effectiveness across specialized applications with quantified performance metrics and corrosion protection validations.
Automotive Chrome
Industrial Hard Chrome
Aerospace Applications
DRAVYOM Competitive Advantages
Superior Safety Standards
Industry-leading safety protocols and containment systems for hexavalent chromium handling and processing
Regulatory Expertise
Comprehensive compliance support for chromium regulations across multiple jurisdictions
Consistent Quality
Reliable high-purity chromium trioxide with exceptional batch-to-batch consistency
Technical Expertise
Specialized chromium chemistry team with decades of electroplating experience
Environmental Leadership
Advanced waste treatment and emission control technologies for responsible operations
Partnership Approach
Collaborative support for chrome plating operations with custom process development