AR Grade Nitric Acid (HNO₃)
Ultra-pure Analytical Reagent grade nitric acid manufactured to meet stringent ACS specifications for precise analytical procedures, oxidative digestions, and high-accuracy laboratory work. Our AR grade HNO₃ delivers exceptional purity and oxidative power for critical analytical applications.
- 68-70% Analytical Grade Concentration
- ACS Grade Standards Compliance
- Ultra-Low Metal Impurities (≤0.000001%)
- Traceable Certificate of Analysis
- Superior Oxidizing Properties (E° = +0.96V)
- Research Grade Quality & Digestion Power
Technical Specifications
Applications
Industry-Specific Grades
DRAVYOM offers specialized nitric acid grades tailored for specific analytical requirements, ensuring optimal performance and regulatory compliance across diverse laboratory applications.
AR Grade (Analytical Reagent)
ACS Grade (Certified)
Trace Metal Grade
Ultra-Pure Grade
Quality Standards
DRAVYOM's AR Grade Nitric Acid is manufactured under stringent quality control protocols, meeting international analytical standards including ACS, ISO, and pharmacopoeia specifications. Our analytical-grade production ensures consistent oxidative performance and regulatory compliance.
Advanced Chemical Properties & Performance
AR Grade Nitric Acid exhibits exceptional oxidizing properties essential for analytical applications. Its ultra-pure composition and precise concentration ensure reliable performance in demanding oxidative procedures and trace metal analysis.
Oxidizing Properties
Physical Properties
Analytical Performance
Purity Specifications
Stability Properties
Performance Characteristics
Detailed performance metrics demonstrate AR Grade HNO₃ superiority in analytical applications with exceptional oxidative power, digestion efficiency, and reproducibility across diverse analytical procedures and testing protocols.
Digestion Performance
Efficiency: 99.9%+ complete matrix destruction
Superior oxidative digestion capabilityMetal Recovery
Recovery rates: 98-102% for trace elements
Exceptional quantitative performanceICP-MS Performance
Background: Sub-ppb detection limits
Ultra-low background interferenceTemperature Range
Working range: 20-150°C operational
Versatile digestion temperature capabilityBatch Reproducibility
Variation: ±0.05% between batches
Outstanding lot-to-lot consistencyShelf Stability
3 years in amber glass containers
Extended analytical grade integritySafety Information
Highly corrosive and strong oxidizing acid that can cause severe burns and fires. Handle in well-ventilated areas with appropriate protective equipment including chemical-resistant gloves, safety goggles, and protective clothing. Avoid contact with organic materials and ensure emergency procedures are in place.
Storage & Handling
Store in original amber glass containers in a cool, dry, well-ventilated area away from organic materials and reducing agents. Keep containers tightly closed and protect from direct sunlight. Use corrosion-resistant storage equipment and ensure proper NOx vapor management systems.
Chemical Mechanisms & Reaction Pathways
Nitric acid exhibits strong oxidizing properties through multiple electron transfer mechanisms, enabling complete oxidative digestion of organic and inorganic matrices for analytical applications.
Oxidative Digestion
Complete mineralization: Organic matrices → CO₂ + H₂O + mineral salts
Quantitative conversion for trace analysisMetal Dissolution
Passivation layer removal and metal oxide formation
Essential for complete sample dissolutionNitration Reactions
Electrophilic substitution with aromatic compounds
Controlled derivatization for analysisRedox Chemistry
Multi-electron transfer processes with variable oxidation states
Versatile oxidative analytical applicationsRegulatory Compliance & Documentation
Comprehensive regulatory compliance ensures global analytical laboratory access with complete documentation packages supporting international standards and analytical method validations.
ACS Specifications
American Chemical Society analytical reagent standards compliance
ISO 6353 Standard
International standard for reagent specifications and testing
USP Grade Available
United States Pharmacopeia specifications for pharmaceutical analysis
REACH Registration
European Union chemical regulation compliance
EPA Method Support
Validated for EPA environmental analytical methods
SDS Documentation
Multi-language Safety Data Sheets (16 sections, GHS compliant)
Technical Support & Value-Added Services
DRAVYOM's analytical chemistry team provides comprehensive digestion method support, troubleshooting assistance, and analytical services to optimize AR Grade HNO₃ performance in your specific analytical applications.
Digestion Method Development
- Microwave digestion optimization
- Open vessel digestion protocols
- Matrix-specific method development
- Temperature and pressure optimization
Analytical Services
- Certificate of Analysis verification
- Custom purity analysis
- Trace metal contamination testing
- Digestion efficiency validation
Technical Support
- Analytical troubleshooting consultation
- Safety and handling guidance
- Method transfer support
- Laboratory safety training
Supply Solutions
- Consistent high-purity batching
- Emergency supply arrangements
- Custom packaging solutions
- Global distribution network
Environmental Impact & Sustainability
Our AR Grade HNO₃ production emphasizes environmental responsibility through sustainable manufacturing practices, NOx emission control, and comprehensive environmental impact management for analytical laboratory operations.
NOx Emission Control
Advanced scrubbing systems for nitrogen oxide capture
Acid Recovery
Spent acid recovery and regeneration programs
Clean Production
Energy-efficient ostwald process with emission controls
Safe Disposal
Comprehensive neutralization and disposal guidance
ISO 14001
Environmental management system certified production
Container Recycling
Amber glass container return and recycling programs
Manufacturing Excellence & Quality Control
DRAVYOM's state-of-the-art analytical reagent manufacturing facility employs advanced distillation and purification technology with continuous monitoring systems to ensure consistent AR Grade HNO₃ quality and performance across all production batches.
Production Process
Multi-stage distillation with ultra-pure water in controlled atmosphere
Precise concentration control and purificationQuality Testing
28-point analytical testing protocol including metals, organics, and trace impurities
ICP-MS verification and ion chromatographyQuality Systems
ISO 9001:2015 quality management with analytical laboratory accreditation
Continuous improvement and method validationPackaging Control
Amber glass containers with inert atmosphere and vapor tight sealing
Light protection and decomposition preventionMarket Applications & Performance Data
Comprehensive analytical laboratory data demonstrating AR Grade HNO₃ effectiveness across diverse applications with quantified performance metrics and analytical method validations.
Digestion Applications
Research Institutions
Environmental Labs
DRAVYOM Competitive Advantages
Superior Oxidizing Power
Consistently exceeds ACS specifications with exceptional oxidative performance for complete matrix digestion
Reliable Supply
Guaranteed availability with strategic inventory management and analytical-grade production scheduling
Analytical Expertise
Dedicated analytical chemistry team provides digestion method development and troubleshooting support
Quality Assurance
Traceable certificates with comprehensive analytical data and digestion method validation support
Global Standards
International compliance with ACS, USP, and EPA specifications for worldwide analytical acceptance
Partnership Approach
Collaborative relationships with analytical laboratories and custom digestion method development services