Heavy Metal Standard for ICP-MS - Certified Reference Material
Certified Premium
Analytical Reagent

Heavy Metal Standard for ICP-MS

Premium heavy metal standard engineered for demanding analytical applications including ICP-MS analysis, trace metal detection, and environmental monitoring. Our certified reference materials deliver exceptional accuracy, consistent performance, and reliable results for critical analytical processes requiring superior precision with stringent quality control standards.

  • Certified Reference Material Quality
  • NIST Traceable Accuracy
  • Multi-Element Standards Available
  • ICP-MS Optimized Matrix
  • Environmental Testing Ready
  • Method Validation Support

Technical Specifications

Standard Type: Certified Reference Material (CRM)
Matrix: 5% HNO₃ in ultrapure water
Element Coverage: Multi-element (Pb, Cd, Hg, As, Cr, Ni)
Concentration Levels: 1-1000 μg/L (customizable)
Uncertainty: ±2% (95% confidence level)
Traceability: NIST SRM certified
Stability: 24 months at 4°C
Instrument Compatibility: ICP-MS, ICP-OES, AAS
Detection Limits: Sub-ppb level validation
Interference: Spectral interference tested
Quality Control: ISO/IEC 17025 accredited
Storage Temperature: 2-8°C
Certificate: Full analytical certificate included
Packaging Options: 125mL, 500mL amber bottles

Applications

ICP-MS Analysis
ICP-OES Spectroscopy
Atomic Absorption
Environmental Testing
Water Quality Analysis
Industrial QC
Method Validation
Calibration Standards
Safety Assessment
Food Safety Testing
Research Applications
Clinical Diagnostics

Industry-Specific Grades

DRAVYOM offers specialized heavy metal standard grades tailored for specific analytical requirements, ensuring optimal performance and regulatory compliance across diverse analytical applications.

CRM Grade
Certification: NIST traceable Uncertainty: ±2% Elements: Multi-element mix Application: Method validation
EPA Grade
Compliance: EPA methods Matrix: 5% HNO₃ Stability: 24 months Application: Environmental analysis
Ultra-Trace Grade
Concentration: Sub-ppb Purity: >99.999% Detection: Ultra-low limits Application: Trace analysis
Custom Grade
Elements: Customer specific Concentration: Tailored Matrix: Custom solution Application: Specialized needs

Quality Standards

DRAVYOM's Heavy Metal Standards are manufactured under stringent quality control protocols, meeting international analytical standards including NIST, ISO, and EPA specifications. Our certified reference materials ensure consistent performance and regulatory compliance.

ISO/IEC 17025 Accredited
NIST Traceable Certification
±2% Measurement Uncertainty
Multi-Element Verification
ICP-MS Optimized Matrix
24-Month Stability
Complete Certificate of Analysis
Temperature-Controlled Storage

Advanced Chemical Properties & Performance

AR Grade Heavy Metal Standard for ICP-MS exhibits exceptional analytical properties essential for mass spectrometry applications. Its certified composition and precise elemental concentrations ensure reliable performance in demanding analytical procedures and trace metal determinations.

Spectroscopic Properties
Matrix: 5% HNO₃ solution
Certification: ISO 17034:2016 compliant
Traceability: NIST SRM traceable
Uncertainty: ±1% (k=2) expanded
Physical Properties
Appearance: Clear colorless solution
pH: ≤1.0
Density (20°C): 1.03 ± 0.01 g/mL
Viscosity: 1.1 ± 0.1 mPa·s
Analytical Performance
Detection Limit: 0.001 µg/L per element
Precision: RSD ≤0.5%
Linearity: R² ≥0.9999
Matrix Effects: Minimized and documented
Purity Specifications
Element Purity: 99.99%+ certified
Spectral Interference: ≤0.001%
Polyatomic Interference: Characterized and documented
Homogeneity: RSD ≤0.3%
Stability Properties
Shelf Life: 3 years (unopened)
Storage Stability: Stable at room temperature
Working Solution: 6 months from opening
Container Compatibility: FEP, PTFE bottles

Performance Characteristics

Detailed performance metrics demonstrate AR Grade Heavy Metal Standard superiority in ICP-MS applications with exceptional analytical accuracy, certified traceability, and reproducibility across diverse mass spectrometry procedures and testing protocols.

ICP-MS Performance

Accuracy: ±1% certified values

Superior mass spectrometry reference
Measurement Precision

Repeatability: RSD ≤0.5%

Exceptional analytical reliability
Matrix Consistency

Homogeneity: RSD ≤0.3% between units

Consistent matrix composition
Temperature Range

Working range: 15-30°C operational

Standard laboratory conditions
Lot Reproducibility

Variation: ±0.5% between lots

Outstanding lot-to-lot consistency
Shelf Stability

3 years under proper storage conditions

Extended certified integrity

Safety Information

Acidic solution containing toxic heavy metals. Handle with appropriate protective equipment including chemical-resistant gloves, safety goggles, and use in well-ventilated areas. Avoid skin contact and inhalation. Ensure proper waste disposal according to environmental regulations.

Toxic Metals
Corrosive Acid
Environmental Hazard

Storage & Handling

Store in original FEP containers at room temperature in a cool, dry, well-ventilated area. Keep containers tightly closed and protect from contamination. Use appropriate trace metal clean handling protocols and maintain chain of custody documentation.

Room temperature storage (15-25°C)
Well-ventilated storage area
Original FEP containers
Trace metal clean protocols

Chemical Mechanisms & Reaction Pathways

Heavy Metal Standard for ICP-MS exhibits controlled metal ion stability and matrix interactions through certified reference mechanisms, enabling precise analytical applications for instrument calibration and quantitative elemental analysis procedures.

Metal Ion Stability

Multi-element matrix with stabilized metal ions in nitric acid solution

NIST-traceable concentration maintenance for ICP-MS
Matrix Compatibility

Optimized acid matrix minimizing spectral interference

Enhanced signal-to-noise ratio for trace analysis
Ionization Control

Consistent ionization efficiency across all metal analytes

Reproducible plasma source performance
Mass Spectrometry Response

Linear calibration curves across analytical concentration ranges

Accurate quantitative elemental determination

Regulatory Compliance & Documentation

Comprehensive regulatory compliance ensures global analytical laboratory access with complete documentation packages supporting international standards and ICP-MS method validations.

NIST Traceability

National Institute of Standards and Technology certified reference values

ISO Guide 34

International standard for reference material producer competence

ISO/IEC 17025

Laboratory testing and calibration competence requirements

REACH Registration

European Union chemical regulation compliance

EPA Method Support

Validated for EPA environmental ICP-MS analytical methods

SDS Documentation

Multi-language Safety Data Sheets (16 sections, GHS compliant)

Technical Support & Value-Added Services

DRAVYOM's ICP-MS specialists provide comprehensive heavy metal standard support, troubleshooting assistance, and analytical services to optimize Heavy Metal Standard performance in your specific analytical applications.

ICP-MS Method Development
  • Calibration curve optimization protocols
  • Matrix effect assessment and correction
  • Interference elimination strategies
  • Quality control chart optimization
Analytical Services
  • Certificate of Analysis verification
  • Custom concentration preparation
  • Stability testing programs
  • Uncertainty budget evaluation
Technical Support
  • ICP-MS troubleshooting consultation
  • Standard handling and dilution training
  • Method transfer support
  • Laboratory QC protocols
Supply Solutions
  • Consistent certified value batching
  • Emergency standard supply arrangements
  • Custom multi-element formulations
  • Global trace metal analysis network

Environmental Impact & Sustainability

Our Heavy Metal Standard for ICP-MS production emphasizes environmental responsibility through sustainable manufacturing practices, heavy metal waste minimization, and comprehensive environmental impact management for analytical laboratory operations.

Clean Production

Controlled preparation environment with minimal heavy metal waste

Metal Recovery

Precious and toxic metal recovery and recycling programs

Sustainable Process

Energy-efficient preparation with emission controls

Safe Disposal

Comprehensive heavy metal treatment and disposal guidance

ISO 14001

Environmental management system certified production

Container Recycling

FEP container return and specialized recycling programs

Manufacturing Excellence & Quality Control

DRAVYOM's state-of-the-art trace metal standard manufacturing facility employs advanced preparation technology with continuous monitoring systems to ensure consistent Heavy Metal Standard quality and performance across all production batches.

Production Process

Gravimetric preparation with ultra-pure metal stocks and acids

Precise concentration control and homogenization
Quality Testing

Multi-technique certification including ICP-MS, ICP-OES validation

Round-robin validation and uncertainty assessment
Quality Systems

ISO 9001:2015 quality management with ISO Guide 34 compliance

Continuous improvement and standard validation
Packaging Control

FEP containers with certified metal-free closures

Contamination prevention and stability maintenance

Market Applications & Performance Data

Comprehensive analytical laboratory data demonstrating Heavy Metal Standard for ICP-MS effectiveness across diverse applications with quantified performance metrics and elemental analysis validations.

ICP-MS Applications
Precision: ±0.5% relative expanded uncertainty Stability: 24-month certified shelf life Linearity: R² >0.9999 calibration curves
Research Institutions
Method Support: 150+ ICP-MS protocols Reproducibility: >99.8% inter-lab agreement Innovation: Advanced trace metal techniques
Environmental Labs
Reliability: 99.9% batch consistency Audit Success: 100% regulatory compliance Efficiency: 60% faster method validation

DRAVYOM Competitive Advantages

Superior Standard Quality

Consistently exceeds specifications with exceptional certified values and measurement uncertainty for ICP-MS applications

Reliable Supply

Guaranteed availability with strategic inventory management and certified standard production scheduling

ICP-MS Expertise

Dedicated trace metal analysis team provides method development and troubleshooting support

Quality Assurance

NIST-traceable certificates with comprehensive uncertainty data and ICP-MS method validation support

Global Standards

International compliance with ISO Guide 34 and NIST specifications for worldwide analytical acceptance

Partnership Approach

Collaborative relationships with analytical laboratories and custom standard development services