Heavy Metal Standard for ICP-MS
Premium heavy metal standard engineered for demanding analytical applications including ICP-MS analysis, trace metal detection, and environmental monitoring. Our certified reference materials deliver exceptional accuracy, consistent performance, and reliable results for critical analytical processes requiring superior precision with stringent quality control standards.
- Certified Reference Material Quality
- NIST Traceable Accuracy
- Multi-Element Standards Available
- ICP-MS Optimized Matrix
- Environmental Testing Ready
- Method Validation Support
Technical Specifications
Applications
Industry-Specific Grades
DRAVYOM offers specialized heavy metal standard grades tailored for specific analytical requirements, ensuring optimal performance and regulatory compliance across diverse analytical applications.
CRM Grade
EPA Grade
Ultra-Trace Grade
Custom Grade
Quality Standards
DRAVYOM's Heavy Metal Standards are manufactured under stringent quality control protocols, meeting international analytical standards including NIST, ISO, and EPA specifications. Our certified reference materials ensure consistent performance and regulatory compliance.
Advanced Chemical Properties & Performance
AR Grade Heavy Metal Standard for ICP-MS exhibits exceptional analytical properties essential for mass spectrometry applications. Its certified composition and precise elemental concentrations ensure reliable performance in demanding analytical procedures and trace metal determinations.
Spectroscopic Properties
Physical Properties
Analytical Performance
Purity Specifications
Stability Properties
Performance Characteristics
Detailed performance metrics demonstrate AR Grade Heavy Metal Standard superiority in ICP-MS applications with exceptional analytical accuracy, certified traceability, and reproducibility across diverse mass spectrometry procedures and testing protocols.
ICP-MS Performance
Accuracy: ±1% certified values
Superior mass spectrometry referenceMeasurement Precision
Repeatability: RSD ≤0.5%
Exceptional analytical reliabilityMatrix Consistency
Homogeneity: RSD ≤0.3% between units
Consistent matrix compositionTemperature Range
Working range: 15-30°C operational
Standard laboratory conditionsLot Reproducibility
Variation: ±0.5% between lots
Outstanding lot-to-lot consistencyShelf Stability
3 years under proper storage conditions
Extended certified integritySafety Information
Acidic solution containing toxic heavy metals. Handle with appropriate protective equipment including chemical-resistant gloves, safety goggles, and use in well-ventilated areas. Avoid skin contact and inhalation. Ensure proper waste disposal according to environmental regulations.
Storage & Handling
Store in original FEP containers at room temperature in a cool, dry, well-ventilated area. Keep containers tightly closed and protect from contamination. Use appropriate trace metal clean handling protocols and maintain chain of custody documentation.
Chemical Mechanisms & Reaction Pathways
Heavy Metal Standard for ICP-MS exhibits controlled metal ion stability and matrix interactions through certified reference mechanisms, enabling precise analytical applications for instrument calibration and quantitative elemental analysis procedures.
Metal Ion Stability
Multi-element matrix with stabilized metal ions in nitric acid solution
NIST-traceable concentration maintenance for ICP-MSMatrix Compatibility
Optimized acid matrix minimizing spectral interference
Enhanced signal-to-noise ratio for trace analysisIonization Control
Consistent ionization efficiency across all metal analytes
Reproducible plasma source performanceMass Spectrometry Response
Linear calibration curves across analytical concentration ranges
Accurate quantitative elemental determinationRegulatory Compliance & Documentation
Comprehensive regulatory compliance ensures global analytical laboratory access with complete documentation packages supporting international standards and ICP-MS method validations.
NIST Traceability
National Institute of Standards and Technology certified reference values
ISO Guide 34
International standard for reference material producer competence
ISO/IEC 17025
Laboratory testing and calibration competence requirements
REACH Registration
European Union chemical regulation compliance
EPA Method Support
Validated for EPA environmental ICP-MS analytical methods
SDS Documentation
Multi-language Safety Data Sheets (16 sections, GHS compliant)
Technical Support & Value-Added Services
DRAVYOM's ICP-MS specialists provide comprehensive heavy metal standard support, troubleshooting assistance, and analytical services to optimize Heavy Metal Standard performance in your specific analytical applications.
ICP-MS Method Development
- Calibration curve optimization protocols
- Matrix effect assessment and correction
- Interference elimination strategies
- Quality control chart optimization
Analytical Services
- Certificate of Analysis verification
- Custom concentration preparation
- Stability testing programs
- Uncertainty budget evaluation
Technical Support
- ICP-MS troubleshooting consultation
- Standard handling and dilution training
- Method transfer support
- Laboratory QC protocols
Supply Solutions
- Consistent certified value batching
- Emergency standard supply arrangements
- Custom multi-element formulations
- Global trace metal analysis network
Environmental Impact & Sustainability
Our Heavy Metal Standard for ICP-MS production emphasizes environmental responsibility through sustainable manufacturing practices, heavy metal waste minimization, and comprehensive environmental impact management for analytical laboratory operations.
Clean Production
Controlled preparation environment with minimal heavy metal waste
Metal Recovery
Precious and toxic metal recovery and recycling programs
Sustainable Process
Energy-efficient preparation with emission controls
Safe Disposal
Comprehensive heavy metal treatment and disposal guidance
ISO 14001
Environmental management system certified production
Container Recycling
FEP container return and specialized recycling programs
Manufacturing Excellence & Quality Control
DRAVYOM's state-of-the-art trace metal standard manufacturing facility employs advanced preparation technology with continuous monitoring systems to ensure consistent Heavy Metal Standard quality and performance across all production batches.
Production Process
Gravimetric preparation with ultra-pure metal stocks and acids
Precise concentration control and homogenizationQuality Testing
Multi-technique certification including ICP-MS, ICP-OES validation
Round-robin validation and uncertainty assessmentQuality Systems
ISO 9001:2015 quality management with ISO Guide 34 compliance
Continuous improvement and standard validationPackaging Control
FEP containers with certified metal-free closures
Contamination prevention and stability maintenanceMarket Applications & Performance Data
Comprehensive analytical laboratory data demonstrating Heavy Metal Standard for ICP-MS effectiveness across diverse applications with quantified performance metrics and elemental analysis validations.
ICP-MS Applications
Research Institutions
Environmental Labs
DRAVYOM Competitive Advantages
Superior Standard Quality
Consistently exceeds specifications with exceptional certified values and measurement uncertainty for ICP-MS applications
Reliable Supply
Guaranteed availability with strategic inventory management and certified standard production scheduling
ICP-MS Expertise
Dedicated trace metal analysis team provides method development and troubleshooting support
Quality Assurance
NIST-traceable certificates with comprehensive uncertainty data and ICP-MS method validation support
Global Standards
International compliance with ISO Guide 34 and NIST specifications for worldwide analytical acceptance
Partnership Approach
Collaborative relationships with analytical laboratories and custom standard development services