AR Grade Giemsa Stain
Analytical Reagent grade Giemsa stain manufactured for blood smear examination, cytology, parasitology, and hematology applications. Our AR grade Giemsa provides reliable staining properties for research applications, clinical diagnostics, and microscopic analysis requiring differential cell visualization.
- Analytical Grade Purity
- Blood Smear Examination
- Hematology Applications
- Parasitology Studies
- Clinical Diagnostics
- Differential Cell Staining
Technical Specifications
Applications
Industry-Specific Grades
DRAVYOM offers specialized Giemsa stain grades tailored for specific diagnostic and research requirements, ensuring optimal performance and regulatory compliance across diverse laboratory applications.
AR Grade (Analytical Reagent)
Clinical Grade
Research Grade
Rapid Stain Grade
Quality Standards
DRAVYOM's AR Grade Giemsa Stain is manufactured under stringent quality control protocols, meeting international diagnostic standards including USP, EP, and clinical laboratory specifications. Our analytical-grade production ensures consistent performance and regulatory compliance.
Advanced Chemical Properties & Performance
AR Grade Giemsa Stain exhibits exceptional differential staining properties essential for hematological and parasitological examination. Its ultra-pure methylene blue azure and eosin composition ensures reliable performance in blood smear staining, malaria diagnosis, and chromosome banding procedures requiring precise cellular differentiation.
Staining Components
Physical Properties
Diagnostic Performance
Quality Specifications
Stability Properties
Performance Characteristics
Detailed performance metrics demonstrate AR Grade Giemsa Stain superiority in hematological diagnostics with exceptional cellular differentiation, reliable parasite detection, and reproducible results across diverse blood analysis and parasitology applications.
Blood Cell Differentiation
WBC types: Clear morphological distinction
Superior diagnostic differentiationParasite Detection
Malaria sensitivity: >95% detection rate
Reliable parasitological diagnosisColor Contrast
Nuclear-cytoplasmic: High contrast ratio
Excellent morphological detailStaining Efficiency
Optimal time: 15-30 minutes
Efficient diagnostic procedureBatch Consistency
Variation: ±2% between batches
Outstanding lot-to-lot reproducibilitypH Stability
Buffered system: Consistent 6.8-7.2 pH
Reliable staining conditionsSafety Information
Contains methylene blue and methanol - may cause mild irritation and is flammable. Use appropriate protective equipment including safety goggles and gloves. Ensure adequate ventilation and avoid ignition sources. Wash thoroughly after handling and avoid inhalation.
Storage & Handling
Store in original amber containers in a cool, dry, dark place away from heat sources and incompatible materials. Prepare working solutions fresh using appropriate buffer. Keep away from ignition sources due to methanol content. Use proper ventilation during preparation and staining procedures.
Chemical Mechanisms & Reaction Pathways
Giemsa stain functions through differential cellular binding mechanisms, enabling selective chromosome visualization and blood cell differentiation with predictable staining pathways for cytological analysis.
DNA-Dye Interaction
Methylene blue and azure dyes bind selectively to phosphate groups in DNA
Blue-purple coloration of chromatin and nucleiProtein Staining
Eosin component binds to cytoplasmic proteins through electrostatic interactions
Pink-red cytoplasm differentiation mechanismpH-Dependent Binding
Optimal staining occurs at pH 6.8 for balanced dye ionization
Critical pH control for selective cellular stainingDifferential Affinity
Component dyes show varying affinity for different cellular structures
Enables clear morphological differentiationRegulatory Compliance & Documentation
Comprehensive regulatory compliance ensures global clinical laboratory access with complete documentation packages supporting international hematology standards and diagnostic method validations.
USP Standards
United States Pharmacopeia specifications for diagnostic staining
CLSI Guidelines
Clinical and Laboratory Standards Institute hematology protocols
FDA Compliance
Food and Drug Administration diagnostic reagent requirements
REACH Registration
European Union chemical regulation compliance
WHO Standards
World Health Organization diagnostic guidelines support
SDS Documentation
Multi-language Safety Data Sheets (16 sections, GHS compliant)
Technical Support & Value-Added Services
DRAVYOM's clinical chemistry team provides comprehensive hematological staining support, Giemsa protocol optimization, and diagnostic method development services for clinical and research applications.
Staining Protocols
- Blood smear staining optimization
- Chromosome analysis procedures
- Staining time and pH optimization
- Differential staining enhancement
Diagnostic Services
- Stain quality verification
- Color intensity standardization
- Morphological assessment support
- Cytological analysis validation
Technical Support
- Clinical laboratory consultation
- Staining technique training
- Quality control protocols
- Troubleshooting guidance
Supply Solutions
- Ready-to-use stain solutions
- Custom concentration formulations
- Stability-optimized packaging
- Global clinical supply network
Environmental Impact & Sustainability
Our Giemsa stain production emphasizes environmental responsibility through sustainable dye chemistry practices, minimal waste generation, and comprehensive environmental impact management for diagnostic applications.
Clean Synthesis
Environmentally conscious dye purification and formulation processes
Solvent Recovery
Methanol recovery programs and organic waste recycling systems
Efficient Production
Optimized stain formulation with minimal environmental impact
Safe Disposal
Comprehensive stain waste disposal and neutralization guidance
ISO 14001
Environmental management system certified production
Container Recycling
Glass container return and recycling programs
Manufacturing Excellence & Quality Control
DRAVYOM's specialized diagnostic reagent facility employs advanced dye chemistry technology with continuous monitoring systems to ensure consistent Giemsa stain quality and diagnostic performance across all production batches.
Stain Formulation
Precise dye component blending with controlled methanol-glycerol ratios
Accurate color balance and staining consistencyQuality Testing
17-point testing including dye content, pH, and staining performance
Spectroscopic verification and morphological assessmentQuality Systems
ISO 9001:2015 quality management with clinical diagnostic validation
Continuous improvement and batch consistency monitoringPackaging Control
Amber glass containers with solvent-resistant closures
Stability preservation and evaporation preventionMarket Applications & Performance Data
Comprehensive clinical laboratory data demonstrating Giemsa stain effectiveness across diverse hematological applications with quantified performance metrics and diagnostic validations.
Clinical Applications
Research Institutions
Clinical Labs
DRAVYOM Competitive Advantages
Superior Staining Quality
Consistently clear cellular differentiation with exceptional morphological detail for accurate hematological diagnosis
Reliable Supply
Guaranteed availability with strategic inventory management and clinical-grade stain production scheduling
Clinical Expertise
Dedicated hematology team provides staining method development and diagnostic troubleshooting support
Quality Assurance
Traceable certificates with comprehensive staining performance data and clinical method validation support
Global Standards
International compliance with USP, CLSI, and WHO specifications for worldwide clinical acceptance
Partnership Approach
Collaborative relationships with clinical laboratories and custom diagnostic method development services