AR Grade Eriochrome Black T
Analytical Reagent grade Eriochrome Black T manufactured for complexometric titrations, water hardness testing, and EDTA titrations. Our AR grade EBT provides reliable metallochromic properties for research applications, analytical procedures, and precise metal ion determination.
- Analytical Grade Purity
- Complexometric Titrations
- Water Hardness Testing
- EDTA Titration Indicator
- Metal Ion Detection
- Research Laboratory Use
Technical Specifications
Applications
Industry-Specific Grades
DRAVYOM offers specialized Eriochrome Black T grades tailored for specific analytical and research requirements, ensuring optimal complexometric performance and regulatory compliance across diverse laboratory applications.
AR Grade (Analytical Reagent)
ACS Grade (Certified)
Titration Grade
Educational Grade
Quality Standards
DRAVYOM's AR Grade Eriochrome Black T is manufactured under stringent quality control protocols, meeting international analytical standards including ACS, ISO, and pharmacopoeia specifications. Our analytical-grade production ensures consistent indicator performance and regulatory compliance.
Advanced Chemical Properties & Performance
AR Grade Eriochrome Black T exhibits exceptional metallochromic indicator properties essential for complexometric titrations. Its ultra-pure composition ensures reliable performance in EDTA titrations, water hardness determination, and metal ion detection requiring precise color change endpoints.
Indicator Properties
Physical Properties
Titration Performance
Purity Specifications
Stability Properties
Performance Characteristics
Detailed performance metrics demonstrate AR Grade Eriochrome Black T superiority in complexometric titrations with exceptional endpoint detection, reliable color transitions, and reproducible results across diverse water hardness and metal analysis applications.
Endpoint Clarity
Transition: Sharp wine red to blue change
Exceptional endpoint visibilityMetal Selectivity
Binding: Selective Ca²⁺/Mg²⁺ indication
Superior metal detectionTitration Accuracy
Precision: ±0.1% hardness determination
Exceptional analytical precisionpH Tolerance
Working range: pH 9-11 optimal
Reliable alkaline performanceBatch Consistency
Variation: ±1% between batches
Outstanding lot-to-lot reproducibilityReaction Speed
Response: Immediate color change
Rapid endpoint detectionSafety Information
Generally safe to handle with standard laboratory precautions. May cause mild eye and skin irritation. Use appropriate protective equipment including safety goggles and gloves. Avoid inhalation of dust and ensure adequate ventilation. Wash thoroughly after handling.
Storage & Handling
Store in original containers in a cool, dry, dark place away from light and moisture. Keep containers tightly closed to prevent degradation. Prepare indicator solutions fresh or store for short periods only. Use amber glassware for light protection.
Chemical Mechanisms & Reaction Pathways
Eriochrome Black T functions as a complexometric indicator through metal-chelation mechanisms, enabling precise EDTA titrations and water hardness determinations with predictable color transition pathways.
Metal Complexation
Forms stable 1:1 chelate complexes with Ca²⁺ and Mg²⁺ ions
Wine-red complex formation at pH 10EDTA Displacement
Metal ions transferred from EBT to EDTA during titration
Blue endpoint indication mechanismpH-Dependent Equilibrium
Optimal performance at pH 10 with ammonia buffer
Sharp color transition for accurate endpointsChelation Stability
Thermodynamically stable complex formation kinetics
Reliable indicator performance in water analysisRegulatory Compliance & Documentation
Comprehensive regulatory compliance ensures global analytical laboratory access with complete documentation packages supporting international water analysis standards and complexometric method validations.
ACS Specifications
American Chemical Society analytical reagent standards compliance
ISO 6059 Standard
International standard for water quality determination methods
ASTM Methods
American Society for Testing and Materials water analysis protocols
REACH Registration
European Union chemical regulation compliance
EPA Method Support
Validated for EPA environmental water analysis methods
SDS Documentation
Multi-language Safety Data Sheets (16 sections, GHS compliant)
Technical Support & Value-Added Services
DRAVYOM's analytical chemistry team provides comprehensive complexometric titration support, water hardness method development, and indicator optimization services for Eriochrome Black T applications.
Water Analysis Methods
- Water hardness titration protocols
- EDTA standardization procedures
- Buffer system optimization
- Endpoint detection training
Analytical Services
- Indicator purity verification
- Color transition validation
- Complexometric method development
- Titration accuracy assessment
Technical Support
- Complexometric troubleshooting consultation
- Indicator solution preparation training
- Method transfer support
- Quality control protocols
Supply Solutions
- Consistent high-purity batching
- Custom indicator concentrations
- Light-protected packaging
- Global analytical supply network
Environmental Impact & Sustainability
Our Eriochrome Black T production emphasizes environmental responsibility through sustainable organic synthesis practices, minimal waste generation, and comprehensive environmental impact management for analytical applications.
Clean Synthesis
Green chemistry principles in indicator compound production
Waste Minimization
Solvent recovery and purification byproduct management
Efficient Production
Optimized synthetic routes with minimal environmental impact
Safe Disposal
Comprehensive disposal guidance for indicator solutions
ISO 14001
Environmental management system certified production
Container Recycling
Glass container return and recycling programs
Manufacturing Excellence & Quality Control
DRAVYOM's specialized organic synthesis facility employs advanced purification technology with continuous quality monitoring to ensure consistent Eriochrome Black T purity and indicator performance across all production batches.
Synthesis Process
Multi-step organic synthesis with controlled azo coupling reactions
Precise pH control and temperature managementQuality Testing
18-point analytical testing including purity, moisture, and indicator performance
HPLC verification and colorimetric analysisQuality Systems
ISO 9001:2015 quality management with analytical method validation
Continuous improvement and batch consistencyPackaging Control
Light-protected containers with moisture barrier closures
Stability preservation and contamination preventionMarket Applications & Performance Data
Comprehensive analytical laboratory data demonstrating Eriochrome Black T effectiveness across diverse complexometric applications with quantified performance metrics and method validations.
Water Analysis Applications
Research Institutions
Quality Control Labs
DRAVYOM Competitive Advantages
Superior Indicator Performance
Consistently sharp color transitions with exceptional complexometric titration accuracy for water hardness determinations
Reliable Supply
Guaranteed availability with strategic inventory management and analytical-grade indicator production scheduling
Analytical Expertise
Dedicated complexometric chemistry team provides method development and water analysis troubleshooting support
Quality Assurance
Traceable certificates with comprehensive indicator performance data and complexometric method validation support
Global Standards
International compliance with ACS, ASTM, and EPA specifications for worldwide analytical acceptance
Partnership Approach
Collaborative relationships with water analysis laboratories and custom complexometric method development services