Calibration Standard pH 10.00 - Analytical Reagent Buffer Solution
Analytical Premium
Analytical Reagent

Calibration Standard pH 10.00

Premium calibration standard pH 10.00 engineered for demanding analytical applications including instrument calibration, analytical chemistry, and research. Our buffer delivers exceptional accuracy, consistent performance, and reliable supply for critical pH measurements requiring superior precision with stringent NIST quality standards.

  • pH 10.00 ± 0.01 Precision
  • Superior Stability
  • NIST Traceable Standards
  • Consistent Batch-to-Batch Quality
  • Calibration Grade
  • Quality Control Applications

Technical Specifications

pH Value: 10.00 ± 0.01 at 25°C
Buffer System: Carbonate/Bicarbonate
Ionic Strength: 0.05 M
Temperature Coefficient: -0.0018 pH/°C
Physical State: Clear, colorless solution
Conductivity: 8.0 ± 0.5 mS/cm
Density (20°C): 1.02 g/cm³
Stability: 12 months at room temperature
Traceability: NIST SRM certified
Uncertainty: ±0.005 pH units
Heavy Metals: ≤1 ppm
Chloride Content: ≤10 ppm
Storage Temperature: 15-25°C
Packaging Options: 100mL, 500mL, 1L bottles

Applications

pH Meter Calibration
Instrument Standardization
Quality Control Testing
Analytical Method Validation
Laboratory Calibration
Reference Standards
Environmental Analysis
Educational Laboratories
Pharmaceutical Testing
Process Control
Water Quality Analysis
Material Testing

Industry-Specific Grades

DRAVYOM offers specialized pH buffer grades tailored for specific analytical requirements, ensuring optimal performance and regulatory compliance across diverse laboratory applications.

Standard Grade
pH: 10.00 ± 0.01 Uncertainty: ±0.005 Stability: 12 months Application: General pH calibration
NIST Traceable
pH: 10.00 ± 0.005 Certified: NIST SRM Traceability: SI units Application: Precision calibration
High Precision Grade
pH: 10.000 ± 0.002 Uncertainty: ±0.001 Temperature: Compensated Application: Research, validation
Reference Grade
pH: 10.000 ± 0.001 Metrological: Traceable Stability: Extended Application: Primary standards

Quality Standards

DRAVYOM's pH Buffer Solution 10.00 is manufactured under stringent quality control protocols, meeting international analytical standards including NIST, ISO, and metrological specifications. Our buffer production ensures consistent performance and regulatory compliance.

ISO 9001:2015 Certified Manufacturing
NIST Traceable Standards
pH 10.00 ± 0.01 Accuracy
Advanced pH Testing
Superior Calibration Standards
Batch-to-Batch Consistency
Traceable Certificate of Analysis
Temperature-Controlled Storage

Advanced Chemical Properties & Performance

AR Grade pH 10 Buffer exhibits exceptional chemical properties essential for analytical applications. Its ultra-pure composition and precise pH maintenance ensure reliable performance in demanding calibration procedures and analytical determinations.

Buffer Properties
pH Value (25°C): 10.00 ± 0.02
Buffer Capacity: 0.2 mol/L equivalent
Temperature Coefficient: -0.0340 pH/°C
Ionic Strength: 0.10 ± 0.01 mol/kg
Physical Properties
Appearance: Clear colorless solution
Density (20°C): 1.003 g/mL
Conductivity: 4.5 ± 0.2 mS/cm
Freezing Point: -0.5°C
Analytical Performance
Calibration Accuracy: ±0.02 pH units
Measurement Precision: ±0.01 pH repeatability
Drift Rate: ≤0.01 pH/hour
Response Time: ≤30 seconds
Purity Specifications
Total Impurities: ≤0.01%
Heavy Metals: ≤1 ppm
Carbonate Content: ≤0.005%
Chloride Content: ≤0.001%
Stability Properties
Shelf Life: 2 years (unopened)
Thermal Stability: Stable 5-50°C
pH Stability: ±0.02 pH over 12 months
Container Compatibility: HDPE, glass bottles

Performance Characteristics

Detailed performance metrics demonstrate AR Grade pH 10 Buffer superiority in analytical applications with exceptional pH stability, precise calibration accuracy, and reproducibility across diverse pH measurement procedures and testing protocols.

Calibration Performance

Accuracy: ±0.02 pH units at 25°C

Superior pH electrode calibration
Measurement Precision

Repeatability: ±0.01 pH units

Exceptional measurement reliability
Buffer Capacity

Resistance: Stable ±3 pH units

Strong buffering action
Temperature Range

Working range: 5-50°C operational

Wide temperature application
Batch Reproducibility

Variation: ±0.01 pH between batches

Outstanding lot-to-lot consistency
Shelf Stability

2 years under proper storage conditions

Extended analytical grade integrity

Safety Information

Alkaline solution that may cause skin and eye irritation. Handle with standard laboratory precautions including gloves, safety goggles, and avoid direct contact with skin or eyes. Use in well-ventilated areas and ensure emergency eyewash stations are accessible.

Irritant
Eye Protection
Glove Protection

Storage & Handling

Store in original containers in a cool, dry area at room temperature. Keep containers tightly closed and avoid exposure to atmospheric CO₂. Use appropriate buffer storage equipment and maintain temperature stability.

Room temperature storage (15-25°C)
CO₂-free environment
Air-tight containers
Avoid contamination

Chemical Mechanisms & Reaction Pathways

pH 10 buffer exhibits controlled alkaline equilibrium mechanisms through borate/carbonate systems, enabling precise analytical applications for pH calibration and alkaline condition maintenance procedures.

Buffer Equilibrium

Henderson-Hasselbalch equation: pH = pKa + log([A⁻]/[HA])

Precise pH control through acid-base equilibrium
Alkaline Stability

Resistance to pH changes from added acids or bases

Consistent alkaline conditions for analysis
Ionic Strength Effects

Controlled ionic environment for electrode function

Optimized for pH meter calibration
Temperature Compensation

Temperature coefficient correction for accurate measurements

Reliable calibration across temperature ranges

Regulatory Compliance & Documentation

Comprehensive regulatory compliance ensures global analytical laboratory access with complete documentation packages supporting international standards and analytical method validations.

NIST Traceability

National Institute of Standards and Technology certified reference values

ISO 6353 Standard

International standard for reagent specifications and testing

USP Grade Available

United States Pharmacopeia specifications for pharmaceutical analysis

REACH Registration

European Union chemical regulation compliance

EPA Method Support

Validated for EPA environmental analytical methods

SDS Documentation

Multi-language Safety Data Sheets (16 sections, GHS compliant)

Technical Support & Value-Added Services

DRAVYOM's analytical chemistry team provides comprehensive pH calibration support, troubleshooting assistance, and analytical services to optimize AR Grade pH 10 Buffer performance in your specific analytical applications.

pH Method Development
  • pH calibration optimization protocols
  • Buffer capacity assessment and validation
  • Temperature compensation guidance
  • Electrode maintenance optimization
Analytical Services
  • Certificate of Analysis verification
  • Custom pH value certification
  • Buffer stability testing
  • Ionic strength validation
Technical Support
  • pH measurement troubleshooting consultation
  • Buffer preparation and storage training
  • Calibration procedure support
  • Laboratory pH system protocols
Supply Solutions
  • Consistent pH value batching
  • Emergency buffer supply arrangements
  • Custom packaging solutions
  • Global distribution network

Environmental Impact & Sustainability

Our AR Grade pH 10 Buffer production emphasizes environmental responsibility through sustainable manufacturing practices, waste minimization, and comprehensive environmental impact management for analytical laboratory operations.

Clean Production

Controlled synthesis environment with minimal waste generation

Buffer Recovery

Efficient neutralization and recovery programs

Sustainable Process

Energy-efficient buffer preparation with emission controls

Safe Disposal

Comprehensive neutralization and disposal guidance

ISO 14001

Environmental management system certified production

Container Recycling

Plastic container return and recycling programs

Manufacturing Excellence & Quality Control

DRAVYOM's state-of-the-art analytical reagent manufacturing facility employs advanced buffer preparation technology with continuous monitoring systems to ensure consistent AR Grade pH 10 Buffer quality and performance across all production batches.

Production Process

Precision buffer preparation with ultra-pure water and reagents

Exact pH control and ionic strength optimization
Quality Testing

12-point pH testing protocol including accuracy, stability, and contamination

Calibrated pH meter verification and traceability
Quality Systems

ISO 9001:2015 quality management with analytical laboratory accreditation

Continuous improvement and pH method validation
Packaging Control

High-density polyethylene containers with CO₂-barrier closures

pH stability and contamination prevention

Market Applications & Performance Data

Comprehensive analytical laboratory data demonstrating AR Grade pH 10 Buffer effectiveness across diverse applications with quantified performance metrics and pH method validations.

pH Applications
Precision: ±0.01 pH units accuracy Stability: 18-month shelf life maintenance Reproducibility: >99.9% measurement consistency
Research Institutions
Calibration Support: 500+ analytical methods Reproducibility: >99.8% inter-lab agreement Innovation: Advanced pH protocols
Quality Control Labs
Reliability: 99.9% batch consistency Audit Success: 100% regulatory compliance Efficiency: 25% faster calibration procedures

DRAVYOM Competitive Advantages

Superior pH Accuracy

Consistently exceeds specifications with exceptional pH stability and buffer capacity for analytical applications

Reliable Supply

Guaranteed availability with strategic inventory management and pH-controlled production scheduling

Analytical Expertise

Dedicated pH chemistry team provides calibration method development and troubleshooting support

Quality Assurance

NIST-traceable certificates with comprehensive pH data and method validation support

Global Standards

International compliance with NIST and ISO specifications for worldwide analytical acceptance

Partnership Approach

Collaborative relationships with analytical laboratories and custom pH buffer development services