Ar Benedicts Solution
Analytical Biochemical
Analytical Reagent

AR Grade Benedict's Solution

Analytical Reagent grade Benedict's solution manufactured for reducing sugar detection, glucose testing, and biochemistry applications. Our AR grade Benedict's reagent provides reliable detection properties for research applications, clinical testing, and precise sugar analysis in laboratory procedures.

  • Analytical Grade Purity
  • Reducing Sugar Detection
  • Glucose Testing Applications
  • Clinical Diagnostics
  • Biochemistry Research
  • Ready-to-Use Solution

Technical Specifications

Primary Component: Copper(II) sulfate pentahydrate
Chemical Formula: CuSO₄·5H₂O + Na₂CO₃ + C₆H₅O₇Na₃
CAS Number: 7758-99-8 (CuSO₄·5H₂O)
Copper Content: 17.3 g/L as CuSO₄·5H₂O
Physical State: Clear blue alkaline solution
pH: 12.0 - 13.0
Density (20°C): 1.15 g/cm³
Stability: Stable at room temperature
Storage Temperature: 15-30°C
Shelf Life: 18 months from manufacture
Detection Limit: 0.05% reducing sugars
Reaction Temperature: Boiling (100°C)
Color Change: Blue to green/yellow/red precipitate
Packaging: 100ml, 250ml, 500ml amber bottles

Applications

Reducing Sugar Detection
Glucose Testing
Urine Sugar Analysis
Clinical Diagnostics
Food Science Testing
Biochemical Analysis
Educational Laboratories
Quality Control
Research Applications
Quantitative Analysis
Carbohydrate Analysis
Sugar Identification

Industry-Specific Grades

DRAVYOM offers specialized Benedict's solution grades tailored for specific analytical requirements, ensuring optimal performance and regulatory compliance across diverse laboratory applications.

AR Grade (Analytical Reagent)
Copper Content: 17.3 g/L pH: 12.0-13.0 Clarity: Crystal clear Application: General analytical procedures
Clinical Grade
Copper Content: 17.3±0.2 g/L Sterility: Tested Endotoxin: <0.25 EU/ml Application: Clinical diagnostics
Quantitative Grade
Copper Content: 17.30±0.05 g/L Sensitivity: 0.01% glucose Precision: ±2% relative Application: Quantitative analysis
Educational Grade
Copper Content: 17.0-17.5 g/L Safety: MSDS included Packaging: Student-safe bottles Application: Teaching laboratories

Quality Standards

DRAVYOM's AR Grade Benedict's Solution is manufactured under stringent quality control protocols, meeting international analytical standards including ACS, ISO, and clinical laboratory specifications. Our analytical-grade production ensures consistent performance and regulatory compliance.

ISO 9001:2015 Certified Manufacturing
Clinical Laboratory Standards
Precise Copper Concentration
Advanced Analytical Testing
High Sensitivity for Glucose
Batch-to-Batch Consistency
Traceable Certificate of Analysis
Temperature-Controlled Logistics

Advanced Chemical Properties & Performance

AR Grade Benedict's Solution exhibits exceptional reducing sugar detection properties. Its ultra-pure composition ensures reliable performance in carbohydrate analysis, providing quantitative detection capabilities for reducing sugars in analytical procedures.

Detection Properties
Detection Range: 0.1-2% reducing sugars
Reaction Time: 5 minutes boiling
Color Development: Blue to red/yellow progression
pH Dependence: Alkaline conditions (pH 10-12)
Physical Properties
Appearance: Clear blue solution
Active Components: CuSO₄, Na₂CO₃, sodium citrate
Working Temperature: Boiling point required
Storage pH: 10.5-11.5
Analytical Performance
Quantitative Analysis: Semi-quantitative results
Sensitivity: 0.1% glucose detection limit
Specificity: All reducing sugars
Reproducibility: ±5% coefficient of variation
Purity Specifications
Copper Content: Specified concentration
Carbonate Content: Analytical grade
Citrate Content: Stabilizing concentration
Impurities: ≤0.01%
Stability Properties
Shelf Life: 2 years (unopened)
Working Solution: Stable for 1 month
Light Sensitivity: Store in amber containers
Temperature Stability: Stable at room temperature

Performance Characteristics

Detailed performance metrics demonstrate AR Grade Benedict's Solution superiority in reducing sugar analysis with exceptional detection sensitivity, reliable color development, and reproducible results across diverse carbohydrate testing procedures.

Detection Sensitivity

Detection limit: 0.1% reducing sugars

Superior carbohydrate detection
Color Development

Clear progression: Blue to red/yellow

Excellent visual differentiation
Reaction Kinetics

Standard time: 5 minutes boiling

Consistent reaction timing
Temperature Dependence

Optimal conditions: Boiling temperature

Controlled reaction conditions
Batch Consistency

Variation: ±3% between batches

Outstanding lot-to-lot reproducibility
Working Range

Quantitative: 0.1-2% sugar solutions

Wide analytical detection range

Safety Information

Contains copper compounds and alkaline salts. May cause eye, skin, and respiratory irritation. Use appropriate protective equipment including chemical-resistant gloves, safety goggles, and lab coats. Ensure adequate ventilation when heating. Avoid direct contact and ingestion.

Irritant
Heating Required
Avoid Direct Contact

Storage & Handling

Store in original amber glass containers in a cool, dry place away from light and heat sources. Keep containers tightly closed to prevent contamination and evaporation. Handle with care during heating procedures and ensure proper ventilation.

Cool storage (15-25°C)
Protect from light
Amber glass containers only
Ventilated area required

Chemical Mechanisms & Reaction Pathways

Benedict's solution exhibits copper-mediated oxidation reactions through alkaline conditions, making it suitable for analytical applications requiring comprehensive reducing sugar detection and quantitative carbohydrate analysis.

Copper Complex Chemistry

Cu²⁺ citrate complex formation in alkaline carbonate medium

Stable analytical reagent complex
Reduction Mechanism

Reducing sugar oxidation: R-CHO + 2Cu²⁺ + 5OH⁻ → R-COO⁻ + Cu₂O + 3H₂O

Quantitative copper reduction
Alkaline Conditions

Sodium carbonate buffer maintaining optimal pH for reaction

Enhanced reaction kinetics
Color Progression

Blue → green → yellow → orange → red precipitate formation

Semi-quantitative visual analysis
Temperature Dependence

Heat-accelerated reaction for complete sugar oxidation

Optimized analytical conditions

Regulatory Compliance & Documentation

Comprehensive regulatory compliance ensures global analytical laboratory access with complete documentation packages supporting international standards and analytical method validations.

ACS Specifications

American Chemical Society analytical reagent standards compliance

ISO 6353 Standard

International standard for reagent specifications and testing

USP Grade Available

United States Pharmacopeia specifications for pharmaceutical analysis

REACH Registration

European Union chemical regulation compliance

EPA Method Support

Validated for EPA environmental analytical methods

SDS Documentation

Multi-language Safety Data Sheets (16 sections, GHS compliant)

Technical Support & Value-Added Services

DRAVYOM's analytical chemistry team provides comprehensive reagent method support, troubleshooting assistance, and analytical services to optimize AR Grade Benedict's Solution performance in your specific analytical applications.

Reagent Method Development
  • Copper complex optimization protocols
  • Temperature control guidance
  • Reaction time optimization
  • pH stability assessment
Analytical Services
  • Certificate of Analysis verification
  • Custom activity testing
  • Copper content validation
  • Alkalinity assessment
Technical Support
  • Carbohydrate analysis consultation
  • Safe handling and storage training
  • Method transfer support
  • Laboratory safety protocols
Performance Services
  • Method validation support
  • System suitability testing
  • Stability studies
  • Quality assurance consultation

Environmental Impact & Sustainability

Our AR Grade Benedict's Solution production emphasizes environmental responsibility through sustainable manufacturing practices, controlled copper management, and comprehensive environmental impact management for analytical laboratory operations.

Copper Recovery

Copper recovery and recycling from spent reagent solutions

Safe Disposal

Comprehensive disposal and neutralization guidance

Clean Production

Energy-efficient preparation with emission controls

Water Treatment

Proper treatment of copper-containing wastewaters

ISO 14001

Environmental management system certified production

Container Recycling

Glass container return and recycling programs

Manufacturing Excellence & Quality Control

DRAVYOM's state-of-the-art analytical reagent manufacturing facility employs advanced preparation technology with continuous monitoring systems to ensure consistent AR Grade Benedict's Solution quality and performance across all production batches.

Production Process

Controlled preparation with copper sulfate, sodium citrate, and sodium carbonate

Precise complex formation and alkalinity control
Quality Testing

18-point analytical testing protocol including copper content and reactivity

AAS verification and functional testing
Quality Systems

ISO 9001:2015 quality management with analytical laboratory accreditation

Continuous improvement and method validation
Packaging Control

Amber glass containers with nitrogen atmosphere protection

Stability preservation and oxidation prevention

Market Applications & Performance Data

Comprehensive analytical laboratory data demonstrating AR Grade Benedict's Solution effectiveness across diverse applications with quantified performance metrics and analytical method validations.

Reducing Sugar Analysis
Detection range: 0.1-2.0% reducing sugars Sensitivity: Visual detection at 0.05% glucose Specificity: All reducing sugars detected
Color Development
Color progression: Blue → green → yellow → red Reaction time: 2-5 minutes at 100°C Stability: Precipitate stable for 30 minutes
Quantitative Analysis
Linearity: R² >0.99 in working range Precision: <3% RSD for replicate analyses Recovery: 98-102% for known standards
Validation Data
Method validation: Standard biochemical protocols Stability: 18+ months proven shelf life Reproducibility: <0.05% RSD batch-to-batch

DRAVYOM Competitive Advantages

Ultra-Pure Reagent Quality

Copper content ±0.1%, alkalinity ±0.05, guaranteed analytical performance

Superior Color Development

Enhanced color progression for accurate semi-quantitative analysis

Multi-Standard Compliance

ACS, USP, and ISO specifications with comprehensive documentation

Reliable Supply Chain

Consistent availability with temperature-controlled logistics

Biochemical Expertise

Analytical chemistry support team with carbohydrate analysis specialists

Environmental Responsibility

Copper recovery programs with controlled environmental impact